MD Scientific Logo
Specialists in chromatography
MD Scientific
MD Scientific
MD Scientific
MD Scientific
 
 
Go to GPC/SEC systems
Go to GPC/SEC detectors & software
Go to DSV systems
Go to HPLC detection systems
Go to UV imaging detector
Go to osmometers
Go to Sievers NOA 280i
Go to gas generators
Peptide synthesizers
Go to Columns
Go to Standards & kits
Go to Service and courses
Go to contact
About us
 

GPC Standards

Viscotek offers a full line of GPC standards for natural and synthetic polymer applications.  PolyCAL™ Standards were developed as part of our  commitment to provide "Complete Solutions for GPC/SEC Applications".  PolyCAL™ Standards free GPC users from tedious standard preparation tasks by providing pre-weighed portions that are both accurate and easy to use.

Pre-Weighed and Ready to Use PolyCAL™ Universal Calibration Standards (UCS)

gpc-standardspic2.jpg (8116 bytes)PolyCAL™ UCS standards consist of 6 sets of 12 individual narrow standards each.  They are designed to be used for column calibrations, either conventional MW calibration with a concentration detector, or Universal Calibration with a viscometer detector.
  • Time efficient, no weighing and no labeling, just add solvent
  • Cost effective, multiple use afford less $ per calibration
  • Accurate, precise and flexible concentration control with bigger vials and larger sample weights
  • Excellent tool for lab-to-lab standardization and cross check
  • One standard per vial, no resolution problems
  • Detail pre-printed labels for lab notebooks (good for GLP/ISO)
  • Broad MW range, 12 fractions provide excellent MW coverage
  • Available for organic (PS, polystyrene) and aqueous (PEO, Polyethylene glycol/oxide) applications

Also Available PolyCAL™ Triple Detector Standards (TDS)

gpc-standardspic3.jpg (8218  bytes)PolyCAL™ TDS standards consist of 6 sets of two standards each, one narrow and one broad. They are designed to be used for calibrating detectors used in triple detection, such as light scattering, viscometers, and refractometers.
  • The narrow standard is particularly useful for determining detector volume offsets and peak broadening parameters.
  • The broad standard is particularly useful for checking the calculations for correct MWD (Mn, Mw, and Mz are reported) and Mark-Houwink parameters, etc.
  • In addition to the weight-average molecular weight Mw, the refractive index increment [dn/dc] and the intrinsic viscosity [h] are reported. These quantities can be used to calibrate, or check the calibration, of any and all three detectors. This response calibration is a must for accurate light scattering and viscometry work.
  • Intrinsic viscosity [h] and refractive index increment [dn/dc] reported for all common solvents.
  • Other benefits regarding accuracy and convenience are similar as listed above for UCS standards.


PolyCAL™ UCS-PS (6 x 12 box)
PolyCAL™ TDS-PS (6 x 2 box)
PolyCAL™ UCS-PEO (6 x 12 box)
PolyCAL™ TDS-PEO (6 x 2 box)

For more details and price, please contact MD Scientific at info@md-scientific.dk or +45 7027 8565.

Top

MD ScientificMD Scientific
MD Scientific
MD Scientific
MD Scientific ApS • Denmark • +45 7027 8565 • info@md-scientific.dk