Viscotek offers a full line of GPC standards for natural and synthetic polymer applications. PolyCAL™ Standards were developed as part of our commitment to provide "Complete Solutions for GPC/SEC Applications". PolyCAL™ Standards free GPC users from tedious standard preparation tasks by providing pre-weighed portions that are both accurate and easy to use.
Pre-Weighed and Ready to Use PolyCAL™ Universal Calibration Standards (UCS)
 PolyCAL™ UCS standards consist of 6 sets of 12 individual narrow standards each. They are designed to be used for column calibrations, either conventional MW calibration with a concentration detector, or Universal Calibration with a viscometer detector.
-
Time efficient, no weighing and no labeling, just add solvent
-
Cost effective, multiple use afford less $ per calibration
-
Accurate, precise and flexible concentration control with bigger vials and larger sample weights
-
Excellent tool for lab-to-lab standardization and cross check
-
One standard per vial, no resolution problems
-
Detail pre-printed labels for lab notebooks (good for GLP/ISO)
-
Broad MW range, 12 fractions provide excellent MW coverage
-
Available for organic (PS, polystyrene) and aqueous (PEO, Polyethylene glycol/oxide) applications
Also Available PolyCAL™ Triple Detector Standards (TDS)
 PolyCAL™ TDS standards consist of 6 sets of two standards each, one narrow and one broad. They are designed to be used for calibrating detectors used in triple detection, such as light scattering, viscometers, and refractometers.
-
The narrow standard is particularly useful for determining detector volume offsets and peak broadening parameters.
-
The broad standard is particularly useful for checking the calculations for correct MWD (Mn, Mw, and Mz are reported) and Mark-Houwink parameters, etc.
-
In addition to the weight-average molecular weight Mw, the refractive index increment [dn/dc] and the intrinsic viscosity [h] are reported. These quantities can be used to calibrate, or check the calibration, of any and all three detectors. This response calibration is a must for accurate light scattering and viscometry work.
-
Intrinsic viscosity [h] and refractive index increment [dn/dc] reported for all common solvents.
-
Other benefits regarding accuracy and convenience are similar as listed above for UCS standards.
PolyCAL™ UCS-PS (6 x 12 box)
PolyCAL™ TDS-PS (6 x 2 box)
PolyCAL™ UCS-PEO (6 x 12 box)
PolyCAL™ TDS-PEO (6 x 2 box)
For more details and price, please contact MD Scientific at info@md-scientific.dk or +45 7027 8565.
|