YL9100 HPLC

 
Young Lin
     
  • Ultra speed data processing by Network HPLC
  • YL-Clarity designed for all you need in the lab
  • Enhanced superior performance
  • Versatile dedicated applications
  • Accurate and reliable data
  • Stylish and compact design

 

f

 

YL9100 system

 

asdf Quaternary Pump
sdf

df Operating principle:parallel dual-plunger pump,Low-pressure gradient

df Number of Solvent:up to 4 solvents

df Gradient formation:4-channel mixing valve

df Composition Precision:< 0.1%

df Composition Accuracy:< 0.5%

fdas Binary Pump

sdfa

df Operating principle:Double parallel dual-plunger pump,

   High-pressure gradient

df Configure with Gradient pump

dfas  Vacuum Degasser
asf

df Number of channel: 4 channels
df Maximum flow rate: 10ml/min per channel
   > 0~2.0ml/min per channel for 70% Gas Removed from Methanol
df Internal volume per channel: 925 ul per channel
df Materials in contact with solvent
   :Teflon AF,PEEK and Glass-filled PTEE

af  Column Compartment
sdf

df Temperature range: 4°C(Cooling) - 90°C
df Temperature stability: ± 0.05°C
df Temperature accuracy: ±0.5°C
df Column capacity: Max. 4 ea of 30 cm column(Analytical)
                              Max. 2 ea of 30 cm column(Semi-Prep)

sdfa UV/Vis Detector
sdf

df Wavelength Range: 190~900nm
df Data collection rate:up to 50Hz
df Noise level: < ±0.5 × 10-5 AU ,254nm,dry cell
df Drift: < 1 × 10-4 AU/hr
df Linearity: > 99.5% for 2.5AU(acetone,254nm)

fds  PDA Detector
sdfa

df No. of PDA Channel:1024
df Wavelength: 190 ~ 950nm
df Noise Level: 2 × 10-5 AU(Empty Cell,1 sec Rise Time,254nm)
df Drift: 2 × 10-4 AU/hr(Baseline Correction), 0.001AU/hr(Room Temp)
df Wavelenth Accuracy: 1nm (HY-1 Holmium Oxide Filter)

asdf RI Detector
df

fsda RI Range: 1.00~1.75 RIU
fsda Noise: ≤ 1.3 × 10-8 RIU
fsda Drift: 0.8 × 10-7 RIU/hr
fsda Linear dynamic range: 80 × 10-5 RIU

 

For more details and price, please contact MD Scientific at info@md-scientific.dk or +45 7027 8565.